Total Solution for On-line

Measurement and Control System

Palma TechnologyAbout productsAlloy Gauge
Alloy Gauge
General Description
Surface treatment plates, such as galvannealed and aluminum plated steel plates, are used for enhancement of corrosion-resistance in steel materials, currently meeting the increasing demands in automobile and construction industry. In particular, the galvannealed steel sheet (GA steel sheet) with more or less coating layer of 10um, excellent in economicalness, corrosion resistance and weldability, is characterized by the variance in color, adhesion and powdering, depending on the percentage of iron over the surface of coating layer.
| Principle & Method

- Surface reflection method

| System Configuration

- Optical Sensor Head

- Linear Motion Actuator

- Sensor Position Controller(local)

- Electrical Controller(electrical room or operation room)

- Can be modified upon customer request

| Special Features

- Measuring non-contact on-line alloying degree

Hansung Aiuminum(in Daegu) Williamson Pyrometer. * Click this pict...
| Actual Delivered

 POSCO(Gwangyang)   No.4CRM 1CAL, 2CAL

 POSCO(Gwangyang)   No.3CRM (2CAL)

 POSCO(Gwangyang)   No.1CGL

| Applications

- Measuring alloying degree of galvannealed steel sheet for interior & exterior materials in automobiles

         and quality control

- Monitoring characteristics of materials in production line

- Quality control in plated steel sheet mill (EGL, ETL)

- Modeling the changes in the degrees of alloying with iron, zinc and aluminum in a coating bath

SPECIFICATIONS
System Specifications
System Performance Measurement Range 1.0% to 20.0%(Fe%)
Unit of Measuremeent 0.01Fe contents(%) in Zn-coated layer
Target Temperature Maximum 200¡É
Update Time 50ms to 2seconds(user selectable)
Response Time <50ms
Reproducibility <±1.0%
Accuracy <±1.0%
Utility Pure Air 5kg⁄§², Dry, Class 3, 2-25A pipe lines
Water Non used
Environment Ambient Temperature 0¡É to 40¡É
Relative Humidity Non-condensing environment for sensors
Signal Ground Maximum 10¥Ø
Frame Ground Maximum 100¥Ø
Power 220VAC, 60Hz, 1Phase
Interface
TCP/IP(standard) Alloy information, Configuration
Digital Input Line status(run, stop, fault), Coil change, Measure start⁄stop
Digital Output Alarm for tolerance(degree of alloy)
Analog Input 4 to 20mA or DC 0V to 10V, Line speed
Analog Output 4 to 20mA, DC 0V to 10V output proportional to degree of alloy
Optical Sensor Specifications
Type Heavy duty aluminum extrusion
Laser Source Solid state diode laser
Laser Safety Class Class ¥²(b)
Laser Visible, Color Visible, Red
Feature Nitrogen(N2) Gas
Relative Humidity Non-condensing environment
Ambient Temperature Range 0¡É to 40¡É
Power 220VAC, 60Hz, 1Phase
Switch Panel Specifications
Type Stand, Stainless steel extrusion
Dimension(mm) 600(W) × 400(D) × 1,000(H)
Front Functional Switch and Lamp Power, Local⁄Remote, Position control(forward,reverse), E-Stop
Required Cooling Pure Air, Dry
Cooling Device Cabinet cooler included
Linear Motion Actuator Specifications
Type Belt type(hidden)
Motor AC Servo Motor
Stroke (standard) 2,000mm
Electrical Controller Specifications
Type 19″ Standard Rack Mount
Dimension(mm) 800(W) ¡¿ 800(D) ¡¿ 2,000(H)
Peripheral Interface D⁄I, D⁄O, A⁄I, A⁄O, RS232 and TCP⁄IP(upon customer request)
Ambient Temperature Range -5¡É to 45¡É
Relative Humidity Maximum 80%RH
Power 220VAC, 60Hz, 1Phase